{"id":21461,"date":"2025-07-16T11:38:00","date_gmt":"2025-07-16T14:38:00","guid":{"rendered":"https:\/\/ostec.blog\/?p=21461"},"modified":"2025-07-16T11:38:00","modified_gmt":"2025-07-16T14:38:00","slug":"cve-2024-53298-falta-de-autorizacion-en-dell-powerscale-expone-los-sistemas-a-accesos-inapropiados","status":"publish","type":"post","link":"https:\/\/ostec.blog\/es\/generico\/cve-2024-53298-falta-de-autorizacion-en-dell-powerscale-expone-los-sistemas-a-accesos-inapropiados\/","title":{"rendered":"CVE-2024-53298: Falta de autorizaci\u00f3n en Dell PowerScale expone los sistemas a accesos inapropiados"},"content":{"rendered":"<p>CVE-2024-53298 expone una falla grave en las versiones 9.5.0.0 a 9.10.0.1 del sistema operativo Dell PowerScale OneFS, responsable de administrar el almacenamiento en cl\u00fasteres. La vulnerabilidad ha sido clasificada como cr\u00edtica, con una puntuaci\u00f3n <a href=\"https:\/\/ostec.blog\/es\/aprendizaje-descubrimiento\/cve-y-cvss-para-la-clasificacion-de-vulnerabilidades-de-seguridad-digital\/\">CVSS<\/a> 9.8, y afecta directamente la funci\u00f3n de exportaci\u00f3n a trav\u00e9s de NFS (Network File System), una tecnolog\u00eda ampliamente utilizada para compartir archivos en entornos empresariales.<\/p>\n<h2>Fallo t\u00e9cnico: falta de verificaci\u00f3n de autorizaci\u00f3n<\/h2>\n<p>El n\u00facleo de la vulnerabilidad es la falta de verificaci\u00f3n de autorizaci\u00f3n en las exportaciones NFS. Cuando se configura correctamente, un entorno NFS requiere que los accesos se validen de acuerdo con permisos previamente definidos. Sin embargo, en las versiones afectadas de OneFS, esta comprobaci\u00f3n se puede omitir por completo, lo que deja espacio para que usuarios maliciosos accedan a los archivos sin el permiso adecuado.<\/p>\n<p>La vulnerabilidad est\u00e1 clasificada como CWE-862 (Missing Authorization), quien describe exactamente este escenario: cuando un sistema realiza acciones protegidas sin verificar si el usuario tiene permiso para hacerlo. Esta falla es especialmente peligrosa en grandes infraestructuras donde m\u00faltiples usuarios y servicios comparten datos confidenciales a trav\u00e9s de NFS.<\/p>\n<h2>Impacto: exposici\u00f3n de datos y comprometimiento de la integridad<\/h2>\n<p>El riesgo que se corre va m\u00e1s all\u00e1 del simple acceso indebido. En un entorno comprometido, un atacante no solo puede leer datos confidenciales, sino tambi\u00e9n modificarlos o incluso eliminarlos, afectando gravemente la integridad de la operaci\u00f3n. Dado que el ataque se puede realizar de forma remota y sin autenticaci\u00f3n, cualquier punto final con acceso a la exportaci\u00f3n NFS vulnerable se convierte en un vector de ataque potencial.<\/p>\n<p>La explotaci\u00f3n de esta falla puede ser silenciosa y persistente, lo que dificulta su detecci\u00f3n temprana y facilita el movimiento lateral dentro de la red.<\/p>\n<h2>Correcciones y medidas de mitigaci\u00f3n<\/h2>\n<p>Dell ha lanzado actualizaciones de seguridad que abordan la falla en las versiones afectadas de OneFS. La compa\u00f1\u00eda recomienda actualizar inmediatamente los sistemas a versiones m\u00e1s nuevas, adem\u00e1s de revisar las pol\u00edticas de exportaci\u00f3n de NFS y aplicar restricciones de acceso por IP o segmentos de red confiables.<\/p>\n<p>Hasta que sea posible una actualizaci\u00f3n, una medida provisional es aislar los sistemas vulnerables de las redes externas y limitar dr\u00e1sticamente los puntos de acceso a las exportaciones NFS.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>CVE-2024-53298 expone una falla grave en las versiones 9.5.0.0 a 9.10.0.1 del sistema operativo Dell PowerScale OneFS, responsable de administrar el almacenamiento en cl\u00fasteres. La vulnerabilidad ha sido clasificada como cr\u00edtica, con una puntuaci\u00f3n CVSS 9.8, y afecta directamente la funci\u00f3n de exportaci\u00f3n a trav\u00e9s de NFS (Network File System), una tecnolog\u00eda ampliamente utilizada para [&hellip;]<\/p>\n","protected":false},"author":14,"featured_media":21459,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1019],"tags":[1778],"class_list":["post-21461","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-generico","tag-cve-es"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.7 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>CVE-2024-53298: Falta de autorizaci\u00f3n en Dell PowerScale expone los sistemas a accesos inapropiados - OSTEC | Seguran\u00e7a digital de resultados<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/ostec.blog\/es\/generico\/cve-2024-53298-falta-de-autorizacion-en-dell-powerscale-expone-los-sistemas-a-accesos-inapropiados\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"CVE-2024-53298: Falta de autorizaci\u00f3n en Dell PowerScale expone los sistemas a accesos inapropiados - OSTEC | Seguran\u00e7a digital de resultados\" \/>\n<meta property=\"og:description\" content=\"CVE-2024-53298 expone una falla grave en las versiones 9.5.0.0 a 9.10.0.1 del sistema operativo Dell PowerScale OneFS, responsable de administrar el almacenamiento en cl\u00fasteres. La vulnerabilidad ha sido clasificada como cr\u00edtica, con una puntuaci\u00f3n CVSS 9.8, y afecta directamente la funci\u00f3n de exportaci\u00f3n a trav\u00e9s de NFS (Network File System), una tecnolog\u00eda ampliamente utilizada para [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/ostec.blog\/es\/generico\/cve-2024-53298-falta-de-autorizacion-en-dell-powerscale-expone-los-sistemas-a-accesos-inapropiados\/\" \/>\n<meta property=\"og:site_name\" content=\"OSTEC | Seguran\u00e7a digital de resultados\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ostec\" \/>\n<meta property=\"article:published_time\" content=\"2025-07-16T14:38:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/ostec.blog\/wp-content\/uploads\/2025\/06\/CVE-2024-53298.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"928\" \/>\n\t<meta property=\"og:image:height\" content=\"534\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Alejandra Villanueva\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ostecsecurity\" \/>\n<meta name=\"twitter:site\" content=\"@ostecsecurity\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/ostec.blog\/es\/generico\/cve-2024-53298-falta-de-autorizacion-en-dell-powerscale-expone-los-sistemas-a-accesos-inapropiados\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/ostec.blog\/es\/generico\/cve-2024-53298-falta-de-autorizacion-en-dell-powerscale-expone-los-sistemas-a-accesos-inapropiados\/\"},\"author\":{\"name\":\"Alejandra Villanueva\",\"@id\":\"https:\/\/ostec.blog\/#\/schema\/person\/882afa77ea19c38d090f993830060c3c\"},\"headline\":\"CVE-2024-53298: Falta de autorizaci\u00f3n en Dell PowerScale expone los sistemas a accesos inapropiados\",\"datePublished\":\"2025-07-16T14:38:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/ostec.blog\/es\/generico\/cve-2024-53298-falta-de-autorizacion-en-dell-powerscale-expone-los-sistemas-a-accesos-inapropiados\/\"},\"wordCount\":410,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/ostec.blog\/#organization\"},\"image\":{\"@id\":\"https:\/\/ostec.blog\/es\/generico\/cve-2024-53298-falta-de-autorizacion-en-dell-powerscale-expone-los-sistemas-a-accesos-inapropiados\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/ostec.blog\/wp-content\/uploads\/2025\/06\/CVE-2024-53298.jpg\",\"keywords\":[\"cve\"],\"articleSection\":[\"Gen\u00e9rico\"],\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/ostec.blog\/es\/generico\/cve-2024-53298-falta-de-autorizacion-en-dell-powerscale-expone-los-sistemas-a-accesos-inapropiados\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/ostec.blog\/es\/generico\/cve-2024-53298-falta-de-autorizacion-en-dell-powerscale-expone-los-sistemas-a-accesos-inapropiados\/\",\"url\":\"https:\/\/ostec.blog\/es\/generico\/cve-2024-53298-falta-de-autorizacion-en-dell-powerscale-expone-los-sistemas-a-accesos-inapropiados\/\",\"name\":\"CVE-2024-53298: Falta de autorizaci\u00f3n en Dell PowerScale expone los sistemas a accesos inapropiados - OSTEC | Seguran\u00e7a digital de resultados\",\"isPartOf\":{\"@id\":\"https:\/\/ostec.blog\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/ostec.blog\/es\/generico\/cve-2024-53298-falta-de-autorizacion-en-dell-powerscale-expone-los-sistemas-a-accesos-inapropiados\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/ostec.blog\/es\/generico\/cve-2024-53298-falta-de-autorizacion-en-dell-powerscale-expone-los-sistemas-a-accesos-inapropiados\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/ostec.blog\/wp-content\/uploads\/2025\/06\/CVE-2024-53298.jpg\",\"datePublished\":\"2025-07-16T14:38:00+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/ostec.blog\/es\/generico\/cve-2024-53298-falta-de-autorizacion-en-dell-powerscale-expone-los-sistemas-a-accesos-inapropiados\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/ostec.blog\/es\/generico\/cve-2024-53298-falta-de-autorizacion-en-dell-powerscale-expone-los-sistemas-a-accesos-inapropiados\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/ostec.blog\/es\/generico\/cve-2024-53298-falta-de-autorizacion-en-dell-powerscale-expone-los-sistemas-a-accesos-inapropiados\/#primaryimage\",\"url\":\"https:\/\/ostec.blog\/wp-content\/uploads\/2025\/06\/CVE-2024-53298.jpg\",\"contentUrl\":\"https:\/\/ostec.blog\/wp-content\/uploads\/2025\/06\/CVE-2024-53298.jpg\",\"width\":928,\"height\":534,\"caption\":\"CVE-2024-53298\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/ostec.blog\/es\/generico\/cve-2024-53298-falta-de-autorizacion-en-dell-powerscale-expone-los-sistemas-a-accesos-inapropiados\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"In\u00edcio\",\"item\":\"https:\/\/ostec.blog\/es\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"CVE-2024-53298: Falta de autorizaci\u00f3n en Dell PowerScale expone los sistemas a accesos inapropiados\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/ostec.blog\/#website\",\"url\":\"https:\/\/ostec.blog\/\",\"name\":\"OSTEC | Seguran\u00e7a digital de resultados\",\"description\":\"Empresa especializada na oferta de produtos e servi\u00e7os de seguran\u00e7a digital.\",\"publisher\":{\"@id\":\"https:\/\/ostec.blog\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/ostec.blog\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/ostec.blog\/#organization\",\"name\":\"OSTEC Business Security\",\"url\":\"https:\/\/ostec.blog\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/ostec.blog\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/ostec.blog\/wp-content\/uploads\/2020\/11\/logo_ostec_250.png\",\"contentUrl\":\"https:\/\/ostec.blog\/wp-content\/uploads\/2020\/11\/logo_ostec_250.png\",\"width\":251,\"height\":67,\"caption\":\"OSTEC Business Security\"},\"image\":{\"@id\":\"https:\/\/ostec.blog\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/ostec\",\"https:\/\/x.com\/ostecsecurity\",\"https:\/\/www.instagram.com\/ostecsecurity\/\",\"https:\/\/linkedin.com\/company\/ostec-security\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/ostec.blog\/#\/schema\/person\/882afa77ea19c38d090f993830060c3c\",\"name\":\"Alejandra Villanueva\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/ostec.blog\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/4ceb189ebb529d4de28f3ab2a156fb63?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/4ceb189ebb529d4de28f3ab2a156fb63?s=96&d=mm&r=g\",\"caption\":\"Alejandra Villanueva\"},\"sameAs\":[\"https:\/\/www.ostec.com.br\"],\"url\":\"https:\/\/ostec.blog\/es\/author\/alejandra-villanueva\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"CVE-2024-53298: Falta de autorizaci\u00f3n en Dell PowerScale expone los sistemas a accesos inapropiados - OSTEC | Seguran\u00e7a digital de resultados","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/ostec.blog\/es\/generico\/cve-2024-53298-falta-de-autorizacion-en-dell-powerscale-expone-los-sistemas-a-accesos-inapropiados\/","og_locale":"es_ES","og_type":"article","og_title":"CVE-2024-53298: Falta de autorizaci\u00f3n en Dell PowerScale expone los sistemas a accesos inapropiados - OSTEC | Seguran\u00e7a digital de resultados","og_description":"CVE-2024-53298 expone una falla grave en las versiones 9.5.0.0 a 9.10.0.1 del sistema operativo Dell PowerScale OneFS, responsable de administrar el almacenamiento en cl\u00fasteres. La vulnerabilidad ha sido clasificada como cr\u00edtica, con una puntuaci\u00f3n CVSS 9.8, y afecta directamente la funci\u00f3n de exportaci\u00f3n a trav\u00e9s de NFS (Network File System), una tecnolog\u00eda ampliamente utilizada para [&hellip;]","og_url":"https:\/\/ostec.blog\/es\/generico\/cve-2024-53298-falta-de-autorizacion-en-dell-powerscale-expone-los-sistemas-a-accesos-inapropiados\/","og_site_name":"OSTEC | Seguran\u00e7a digital de resultados","article_publisher":"https:\/\/www.facebook.com\/ostec","article_published_time":"2025-07-16T14:38:00+00:00","og_image":[{"width":928,"height":534,"url":"https:\/\/ostec.blog\/wp-content\/uploads\/2025\/06\/CVE-2024-53298.jpg","type":"image\/jpeg"}],"author":"Alejandra Villanueva","twitter_card":"summary_large_image","twitter_creator":"@ostecsecurity","twitter_site":"@ostecsecurity","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/ostec.blog\/es\/generico\/cve-2024-53298-falta-de-autorizacion-en-dell-powerscale-expone-los-sistemas-a-accesos-inapropiados\/#article","isPartOf":{"@id":"https:\/\/ostec.blog\/es\/generico\/cve-2024-53298-falta-de-autorizacion-en-dell-powerscale-expone-los-sistemas-a-accesos-inapropiados\/"},"author":{"name":"Alejandra Villanueva","@id":"https:\/\/ostec.blog\/#\/schema\/person\/882afa77ea19c38d090f993830060c3c"},"headline":"CVE-2024-53298: Falta de autorizaci\u00f3n en Dell PowerScale expone los sistemas a accesos inapropiados","datePublished":"2025-07-16T14:38:00+00:00","mainEntityOfPage":{"@id":"https:\/\/ostec.blog\/es\/generico\/cve-2024-53298-falta-de-autorizacion-en-dell-powerscale-expone-los-sistemas-a-accesos-inapropiados\/"},"wordCount":410,"commentCount":0,"publisher":{"@id":"https:\/\/ostec.blog\/#organization"},"image":{"@id":"https:\/\/ostec.blog\/es\/generico\/cve-2024-53298-falta-de-autorizacion-en-dell-powerscale-expone-los-sistemas-a-accesos-inapropiados\/#primaryimage"},"thumbnailUrl":"https:\/\/ostec.blog\/wp-content\/uploads\/2025\/06\/CVE-2024-53298.jpg","keywords":["cve"],"articleSection":["Gen\u00e9rico"],"inLanguage":"es","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/ostec.blog\/es\/generico\/cve-2024-53298-falta-de-autorizacion-en-dell-powerscale-expone-los-sistemas-a-accesos-inapropiados\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/ostec.blog\/es\/generico\/cve-2024-53298-falta-de-autorizacion-en-dell-powerscale-expone-los-sistemas-a-accesos-inapropiados\/","url":"https:\/\/ostec.blog\/es\/generico\/cve-2024-53298-falta-de-autorizacion-en-dell-powerscale-expone-los-sistemas-a-accesos-inapropiados\/","name":"CVE-2024-53298: Falta de autorizaci\u00f3n en Dell PowerScale expone los sistemas a accesos inapropiados - OSTEC | Seguran\u00e7a digital de resultados","isPartOf":{"@id":"https:\/\/ostec.blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/ostec.blog\/es\/generico\/cve-2024-53298-falta-de-autorizacion-en-dell-powerscale-expone-los-sistemas-a-accesos-inapropiados\/#primaryimage"},"image":{"@id":"https:\/\/ostec.blog\/es\/generico\/cve-2024-53298-falta-de-autorizacion-en-dell-powerscale-expone-los-sistemas-a-accesos-inapropiados\/#primaryimage"},"thumbnailUrl":"https:\/\/ostec.blog\/wp-content\/uploads\/2025\/06\/CVE-2024-53298.jpg","datePublished":"2025-07-16T14:38:00+00:00","breadcrumb":{"@id":"https:\/\/ostec.blog\/es\/generico\/cve-2024-53298-falta-de-autorizacion-en-dell-powerscale-expone-los-sistemas-a-accesos-inapropiados\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/ostec.blog\/es\/generico\/cve-2024-53298-falta-de-autorizacion-en-dell-powerscale-expone-los-sistemas-a-accesos-inapropiados\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/ostec.blog\/es\/generico\/cve-2024-53298-falta-de-autorizacion-en-dell-powerscale-expone-los-sistemas-a-accesos-inapropiados\/#primaryimage","url":"https:\/\/ostec.blog\/wp-content\/uploads\/2025\/06\/CVE-2024-53298.jpg","contentUrl":"https:\/\/ostec.blog\/wp-content\/uploads\/2025\/06\/CVE-2024-53298.jpg","width":928,"height":534,"caption":"CVE-2024-53298"},{"@type":"BreadcrumbList","@id":"https:\/\/ostec.blog\/es\/generico\/cve-2024-53298-falta-de-autorizacion-en-dell-powerscale-expone-los-sistemas-a-accesos-inapropiados\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"In\u00edcio","item":"https:\/\/ostec.blog\/es\/"},{"@type":"ListItem","position":2,"name":"CVE-2024-53298: Falta de autorizaci\u00f3n en Dell PowerScale expone los sistemas a accesos inapropiados"}]},{"@type":"WebSite","@id":"https:\/\/ostec.blog\/#website","url":"https:\/\/ostec.blog\/","name":"OSTEC | Seguran\u00e7a digital de resultados","description":"Empresa especializada na oferta de produtos e servi\u00e7os de seguran\u00e7a digital.","publisher":{"@id":"https:\/\/ostec.blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/ostec.blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/ostec.blog\/#organization","name":"OSTEC Business Security","url":"https:\/\/ostec.blog\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/ostec.blog\/#\/schema\/logo\/image\/","url":"https:\/\/ostec.blog\/wp-content\/uploads\/2020\/11\/logo_ostec_250.png","contentUrl":"https:\/\/ostec.blog\/wp-content\/uploads\/2020\/11\/logo_ostec_250.png","width":251,"height":67,"caption":"OSTEC Business Security"},"image":{"@id":"https:\/\/ostec.blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/ostec","https:\/\/x.com\/ostecsecurity","https:\/\/www.instagram.com\/ostecsecurity\/","https:\/\/linkedin.com\/company\/ostec-security"]},{"@type":"Person","@id":"https:\/\/ostec.blog\/#\/schema\/person\/882afa77ea19c38d090f993830060c3c","name":"Alejandra Villanueva","image":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/ostec.blog\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/4ceb189ebb529d4de28f3ab2a156fb63?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/4ceb189ebb529d4de28f3ab2a156fb63?s=96&d=mm&r=g","caption":"Alejandra Villanueva"},"sameAs":["https:\/\/www.ostec.com.br"],"url":"https:\/\/ostec.blog\/es\/author\/alejandra-villanueva\/"}]}},"_links":{"self":[{"href":"https:\/\/ostec.blog\/es\/wp-json\/wp\/v2\/posts\/21461","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ostec.blog\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ostec.blog\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ostec.blog\/es\/wp-json\/wp\/v2\/users\/14"}],"replies":[{"embeddable":true,"href":"https:\/\/ostec.blog\/es\/wp-json\/wp\/v2\/comments?post=21461"}],"version-history":[{"count":4,"href":"https:\/\/ostec.blog\/es\/wp-json\/wp\/v2\/posts\/21461\/revisions"}],"predecessor-version":[{"id":21474,"href":"https:\/\/ostec.blog\/es\/wp-json\/wp\/v2\/posts\/21461\/revisions\/21474"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ostec.blog\/es\/wp-json\/wp\/v2\/media\/21459"}],"wp:attachment":[{"href":"https:\/\/ostec.blog\/es\/wp-json\/wp\/v2\/media?parent=21461"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ostec.blog\/es\/wp-json\/wp\/v2\/categories?post=21461"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ostec.blog\/es\/wp-json\/wp\/v2\/tags?post=21461"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}